AutoCAD Electrical has multiple schematic reports that you can run.
The Bill of Material reports report only components with assigned BOM information. These reports provide the following BOM-related features:
If you marked components and/or terminals with location codes, you can make good use of this report. This report first extracts component, terminal, location code, and wire connection information from every drawing in the project set. Then it displays a location list dialog box where you can make your report's "from" and "to" location selections. All the location codes AutoCAD Electrical found on the drawing set are listed on each side of this dialog box. Location "(??)" is also included in the list if AutoCAD Electrical found any component or stand-alone terminal that did not have an assigned location code.
This report extracts the component wire connection data and displays it in a dialog box. Each entry shows a connection to a component, the wire number, component tag name, terminal pin number, component location code (if present), and the layer that the connected wire is on.
This report extracts plug/jack connection reports and optionally generates pin charts. Since each wire tied to each connector pin displays in the report, each pin has two entries. One entry is for the 'in' wire and the other is for the 'out' wire. To create a more useful report, select the PIN chart 'on' radio button at the bottom of the Report Generator dialog box. Make sure the Remove duplicated pin numbers toggle is checked and click OK. It reformats the report so each pin is listed only once.
This report lists each PLC module and its beginning and ending I/O address numbers. It scans your drawing set and returns all individual I/O connection points it finds. It includes up to five lines of description text and the connected wire number for each I/O point.
This report scans the selected drawings and returns information about any components connected to PLC I/O points. Data for the report starts at each wire connection point and follows the connected wire. The first terminal symbol, fuse symbol, or connector symbol that is hit reports in the column marked with default "TERMTAG" label. The first schematic component reports in the column with the "CMPTAG" label. If there are multiple instances, the one closest to the PLC I/O point is the one that shows up in the report column.
This report extracts the component wire connection data and displays it in a dialog box. Each entry shows a connection to a component, the wire number, component tag name, terminal pin number, component location code (if present), and the layer that the connected wire is on.
Generates schematic reports, such as Bills of Material, Component lists, Wire From/To, and PLC descriptions.
Select which drawings to process. The report displays options to:

.
The Bill of Material reports report only components with assigned BOM information.
Toolbar: Main Electrical 2 
Command entry: AESCHEMATICREPORTSelect Bill of Material from the report list.
Specify whether to process the project or the active drawing.
By default, the report lists schematic components. Select a different Category to run the report for one-line, one-line bus-tap, hydraulic, pneumatic, P&ID, or user-defined components. These components are each identified by a unique WDTYPE attribute value.
| Include Cables | Specifies to include cable information in the report. |
| Include Connectors | Specifies to include connector information in the report. |
| Include Jumpers | Specifies to include jumper information in the report. |
| All the above | Specifies to cable, connector, and jumper information in the report. |
| List terminal numbers | Lists each individual Tag-ID and terminal number combination if selected. If unselected (default), the terminals are combined on the same Tag-ID strip into a single entry with a quantity. |
| Normal Tallied Format | Identical component or component/assemblies are tallied and reported as single line items (example: Red push-button operator 800EP-F4 with 800E-A3L latch and two 800E-3X10 N.O. contact blocks). |
| Normal Tallied Format (Group by Installation/Location) | Identical component or component/assemblies with the same installation/location codes are tallied and reported as single line items. |
| Display in Tallied Purchase List Format | Each part becomes its own line item (example: no longer any sub-assembly items) and each is tallied across all component types. For example, all 800E-3X10 N.O. contact blocks for all components are reported as a single line item. |
| Display in By TAG Format | All instances of a given component-ID or terminal tag are processed together and then reported as a single entry. |
Extracts only the information for components with specific installation values. Indicate to process all components that carry part number values, components without an installation code, or only components marked with a location code that matches that entered in the edit box. Wild-cards are supported.
Once you pick Named Installation, type the installation code in the box or click List: Drawing or List: Project to select from a list of used installation codes. You can also create a report from multiple installation codes. AutoCAD Electrical automatically creates a comma-delimited list for the named installation search.
Extracts only the information for components with specific location values. Indicate to process all components that carry part number values, components without a location code, or only components marked with a location code that matches that entered in the edit box. For example, BOM report for components marked "OP STA 2". Wild-cards are supported.
Once you pick Named Location, type the location code in the box or click List: Drawing or List: Project to select from a list of used location codes. You can also create a report from multiple location codes. AutoCAD Electrical automatically creates a comma-delimited list for the named location search.
Specifies for AutoCAD Electrical to update the project database to include any out-of-date drawing files.
Changes the format of the extracted data. The subdialog box lists the format files to select from.
This project-wide cable conductor report gives a report listing all of the cable marker tags (parent tags) found.
Toolbar: Main Electrical 2 
Command entry: AESCHEMATICREPORTSelect Cable Summary from the report list.
By default, the report lists schematic components. Select a different Category to run the report for one-line, one-line bus-tap, hydraulic, pneumatic, P&ID, or user-defined components. These components are each identified by a unique WDTYPE attribute value.
Extracts only the information for components with specific installation values. Indicate to process all components that carry part number values, components without an installation code, or only components marked with a location code that matches that entered in the edit box. Wild-cards are supported.
Once you pick Named Installation, type the installation code in the box or click List: Drawing or List: Project to select from a list of used installation codes. You can also create a report from multiple installation codes. AutoCAD Electrical automatically creates a comma-delimited list for the named installation search.
Extracts only the information for components with specific location values. Indicate to process all components that carry part number values, components without a location code, or only components marked with a location code that matches that entered in the edit box. For example, BOM report for components marked "OP STA 2". Wild-cards are supported.
Once you pick Named Location, type the location code in the box or click List: Drawing or List: Project to select from a list of used location codes. You can also create a report from multiple location codes. AutoCAD Electrical automatically creates a comma-delimited list for the named location search.
Specifies for AutoCAD Electrical to update the project database to include any out-of-date drawing files.
Changes the format of the extracted data. The subdialog box lists the format files to select from.
This project-wide cable conductor report lists the "from / to" for each cable conductor. It also lists the parent cable number of the conductor, conductor color code, and wire number (if present).
Toolbar: Main Electrical 2 
Command entry: AESCHEMATICREPORTSelect Cable From/To from the report list.
Specify whether to process the project, the active drawing, or selected cables.
By default, the report lists schematic components. Select a different Category to run the report for one-line, one-line bus-tap, hydraulic, pneumatic, P&ID, or user-defined components. These components are each identified by a unique WDTYPE attribute value.
Specifies for AutoCAD Electrical to update the project database to include any out-of-date drawing files.
Changes the format of the extracted data. The dialog box lists the format files to select from.
Schematic PLC I/O component connection
This report scans the selected drawings and returns information about any components connected to PLC I/O points. Data for the report starts at each wire connection point and follows the connected wire. The first terminal symbol, fuse symbol, or connector symbol that is hit reports in the column marked with default "TERMTAG" label. The first schematic component reports in the column with the "CMPTAG" label. If there are multiple instances, the one closest to the PLC I/O point is the one that shows up in the report column.
Toolbar: Main Electrical 2 
Command entry: AESCHEMATICREPORTSelect PLC I/O Component Connection from the report list.
Specify whether to process the project or the active drawing.
Extracts only the information for components with specific installation values. Indicate to process all components that carry part number values, components without an installation code, or only components marked with a location code that matches that entered in the edit box. Wild-cards are supported.
Once you pick Named Installation, type the installation code in the box or click List: Drawing or List: Project to select from a list of used installation codes. You can also create a report from multiple installation codes. AutoCAD Electrical automatically creates a comma-delimited list for the named installation search.
Extracts only the information for components with specific location values. Indicate to process all components that carry part number values, components without a location code, or only components marked with a location code that matches that entered in the edit box. For example, BOM report for components marked "OP STA 2". Wild-cards are supported.
Once you pick Named Location, type the location code in the box or click List: Drawing or List: Project to select from a list of used location codes. You can also create a report from multiple location codes. AutoCAD Electrical automatically creates a comma-delimited list for the named location search.
Lists drawings that appear to be out-of-date with the wire connection table of the project.
Specifies for AutoCAD Electrical to update the wire connection table to include any out-of-date drawing files.
Changes the format of the extracted data. The subdialog box lists the format files to select from.
This report extracts the component wire connection data and shows it in a dialog box. Each entry shows a connection to a component, the wire number, component tag name, terminal pin number, component location code (if present), and the layer that the connected wire is on.
Toolbar: Main Electrical 2 
Command entry: AESCHEMATICREPORTSelect Component Wire List from the report list.
Specify whether to process the project, active drawing, or select components.
Specifies to include stand-alone terminals or plug-jack connectors in the report.
Extracts only the information for components with specific installation values. Indicate to process all components that carry part number values, components without an installation code, or only components marked with a location code that matches that entered in the edit box. Wild-cards are supported.
Once you pick Named Installation, type the installation code in the box or click List: Drawing or List: Project to select from a list of used installation codes. You can also create a report from multiple installation codes. AutoCAD Electrical automatically creates a comma-delimited list for the named installation search.
Extracts only the information for components with specific location values. Indicate to process all components that carry part number values, components without a location code, or only components marked with a location code that matches that entered in the edit box. For example, BOM report for components marked "OP STA 2". Wild-cards are supported.
Once you pick Named Location, type the location code in the box or click List: Drawing or List: Project to select from a list of used location codes. You can also create a report from multiple location codes. AutoCAD Electrical automatically creates a comma-delimited list for the named location search.
Lists drawings that appear to be out-of-date with the wire connection table of the project.
Specifies for AutoCAD Electrical to update the wire connection table to include any out-of-date drawing files.
Changes the format of the extracted data. The subdialog box lists the format files to select from.
AutoCAD Electrical extracts the component wire connection data and displays it in a dialog box. Each entry shows a connection to a component, the wire number, component tag name, terminal pin number, component location code (if present), and the layer that the connected wire is on.
Toolbar: Main Electrical 2 
Command entry: AESCHEMATICREPORTSelect Connector Details from the report list.
Specify whether to process the project or a single pick.
By default, the report lists schematic components. Select a different Category to run the report for one-line, one-line bus-tap, hydraulic, pneumatic, P&ID, or user-defined components. These components are each identified by a unique WDTYPE attribute value.
Extracts only the information for components with specific installation values. Indicate to process all components that carry part number values, components without an installation code, or only components marked with a location code that matches that entered in the edit box. Wild cards are supported.
After you click Named Installation, type the installation code in the box, or click List: Drawing or List: Project to select from a list of used installation codes. You can also create a report from multiple installation codes. AutoCAD Electrical automatically creates a comma-delimited list for the named installation search.
Extracts only the information for components with specific location values. Indicate to process all components that carry part number values, components without a location code, or only components marked with a location code that matches that entered in the edit box. For example, BOM report for components marked "OP STA 2". Wild cards are supported.
After you click Named Location, type the location code in the box, or click List: Drawing or List: Project to select from a list of used location codes. You can also create a report from multiple location codes. AutoCAD Electrical automatically creates a comma-delimited list for the named location search.
Specifies for AutoCAD Electrical to update the project database to include any out-of-date drawing files.
Changes the format of the extracted data. The dialog box lists the format files to select from.
This report extracts plug/jack connection reports and optionally generates pin charts. Since each wire tied to each connector pin displays in the report, each pin has two entries - one for the 'in' wire and one for the 'out' wire. To create a more useful report, select the PIN chart 'on' radio button at the bottom of the Report Generator dialog box. Make sure the Remove duplicated pin numbers toggle is checked and click OK. It reformats the report so each pin is listed only once.
Toolbar: Main Electrical 2 
Command entry: AESCHEMATICREPORTSelect Connector Plug from the report list.
Specify whether to process the project, the active drawing, or selected wires.
By default, the report lists schematic components. Select a different Category to run the report for one-line, one-line bus-tap, hydraulic, pneumatic, P&ID, or user-defined components. These components are each identified by a unique WDTYPE attribute value.
Extracts only the information for components with specific installation values. Indicate to process all components that carry part number values, components without an installation code, or only components marked with a location code that matches that entered in the edit box. Wild cards are supported.
After you click Named Installation, type the installation code in the box, or click List: Drawing or List: Project to select from a list of used installation codes. You can also create a report from multiple installation codes. AutoCAD Electrical automatically creates a comma-delimited list for the named installation search.
Extracts only the information for components with specific location values. Indicate to process all components that carry part number values, components without a location code, or only components marked with a location code that matches that entered in the edit box. For example, BOM report for components marked "OP STA 2." Wild cards are supported.
After you click Named Location, type the location code in the box, or click List: Drawing or List: Project to select from a list of used location codes. You can also create a report from multiple location codes. AutoCAD Electrical automatically creates a comma-delimited list for the named location search.
Lists drawings that appear to be out-of-date with the wire connection table of the project.
Specifies for AutoCAD Electrical to update the wire connection table to include any out-of-date drawing files.
Changes the format of the extracted data. The dialog box lists the format files to select from.
This report lists a single line for each connector tag along with pins used, maximum pins allowed (if the parent carries the PINLIST information), and a list of any repeated pin numbers used. You can run this report across the project or for a single component.
Toolbar: Main Electrical 2 
Command entry: AESCHEMATICREPORTSelect Connector Summary from the report list.
Specify whether to process the project or a single pick.
By default, the report lists schematic components. Select a different Category to run the report for one-line, one-line bus-tap, hydraulic, pneumatic, P&ID, or user-defined components. These components are each identified by a unique WDTYPE attribute value.
Extracts only the information for components with specific installation values. Indicate to process all components that carry part number values, components without an installation code, or only components marked with a location code that matches that entered in the edit box. Wild cards are supported.
After you click Named Installation, type the installation code in the box, or click List: Drawing or List: Project to select from a list of used installation codes. You can also create a report from multiple installation codes. AutoCAD Electrical automatically creates a comma-delimited list for the named installation search.
Extracts only the information for components with specific location values. Indicate to process all components that carry part number values, components without a location code, or only components marked with a location code that matches that entered in the edit box. For example, BOM report for components marked "OP STA 2." Wild cards are supported.
After you click Named Location, type the location code in the box, or click List: Drawing or List: Project to select from a list of used location codes. You can also create a report from multiple location codes. AutoCAD Electrical automatically creates a comma-delimited list for the named location search.
Specifies for AutoCAD Electrical to update the project database to include any out-of-date drawing files.
Changes the format of the extracted data. The dialog box lists the format files to select from.
This report extracts the component wire connection data and displays it in a dialog box. Each entry shows a connection to a component, the wire number, component tag name, terminal pin number, component location code (if present), and the layer that the connected wire is on.
Toolbar: Main Electrical 2 
Command entry: AESCHEMATICREPORTSelect Component from the report list.
Specify whether to process the project or the active drawing.
By default, the report lists schematic components. Select a different Category to run the report for one-line, one-line bus-tap, hydraulic, pneumatic, P&ID, or user-defined components. These components are each identified by a unique WDTYPE attribute value.
Specifies to include components, cable markers, or connectors in the report. You can also indicate to include the children for the selected options.
Extracts only the information for components with specific installation values. Indicate to process all components that carry part number values, components without an installation code, or only components marked with a location code that matches that entered in the edit box. Wild cards are supported.
After you click Named Installation, type the installation code in the box, or click List: Drawing or List: Project to select from a list of used installation codes. You can also create a report from multiple installation codes. AutoCAD Electrical automatically creates a comma-delimited list for the named installation search.
Extracts only the information for components with specific location values. Indicate to process all components that carry part number values, components without a location code, or only components marked with a location code that matches that entered in the edit box. For example, BOM report for components marked "OP STA 2." Wild cards are supported.
After you click Named Location, type the location code in the box, or click List: Drawing or List: Project to select from a list of used location codes. You can also create a report from multiple location codes. AutoCAD Electrical automatically creates a comma-delimited list for the named location search.
Specifies for AutoCAD Electrical to update the project database to include any out-of-date drawing files.
Changes the format of the extracted data. The dialog box lists the format files to select from.
Schematic missing bill of material
Components that do not carry catalog information can be identified in two ways:
Adds diamond shaped temporary graphics to mark components that do not carry catalog number assignments.
Command entry: AEMISSINGCATREPORTClick Show.
Schematic missing bill of material report
Extracts the information from the active drawing or project and displays a list of parent or stand-alone components without catalog information.
The report can be accessed in two ways:
Toolbar: Main Electrical 2 
Command entry: AESCHEMATICREPORTSelect Missing Bill of Material from the report list.
Missing Catalog Data command
Command entry: AEMISSINGCATREPORT
Click Report.
Missing Bill of Material is preselected from the report list.
Specify whether to process the project or the active drawing.
By default, the report lists schematic components. Select a different Category to run the report for one-line, one-line bus-tap, hydraulic, pneumatic, P&ID, or user-defined components. These components are each identified by a unique WDTYPE attribute value.
Specifies to include components, cable markers, connectors, or terminals in the report.
Extracts only the information for components with specific installation values. Indicate to process all components that carry part number values, components without an installation code, or only components marked with a location code that matches that entered in the edit box. Wild cards are supported.
After you click Named Installation, type the installation code in the box, or click List: Drawing or List: Project to select from a list of used installation codes. You can also create a report from multiple installation codes. AutoCAD Electrical automatically creates a comma-delimited list for the named installation search.
Extracts only the information for components with specific location values. Indicate to process all components that carry part number values, components without a location code, or only components marked with a location code that matches that entered in the edit box. For example, BOM report for components marked "OP STA 2." Wild cards are supported.
After you click Named Location, type the location code in the box, or click List: Drawing or List: Project to select from a list of used location codes. You can also create a report from multiple location codes. AutoCAD Electrical automatically creates a comma-delimited list for the named location search.
Specifies for AutoCAD Electrical to update the project database to include any out-of-date drawing files.
Changes the format of the extracted data. The dialog box lists the format files to select from.
If you marked components and/or terminals with location codes, you can make good use of this report. AutoCAD Electrical first extracts component, terminal, location code, and wire connection information from every drawing in the project set. Then it displays a location list dialog box where you can make your report's "from" and "to" location selections. All the location codes AutoCAD Electrical found on the drawing set are listed on each side of this dialog box. Location "(??)" is also included in the list if AutoCAD Electrical found any component or stand-alone terminal that didn't have an assigned location code.
Toolbar: Main Electrical 2 
Command entry: AESCHEMATICREPORTSelect Wire From/To from the report list.
Specify whether to process the project, the active drawing, or selected wires.
By default, the report lists schematic components. Select a different Category to run the report for one-line, one-line bus-tap, hydraulic, pneumatic, P&ID, or user-defined components. These components are each identified by a unique WDTYPE attribute value.
Lists drawings that appear to be out-of-date with the wire connection table of the project.
Specifies for AutoCAD Electrical to update the wire connection table to include any out-of-date drawing files.
Changes the format of the extracted data. The dialog box lists the format files to select from.
Schematic PLC I/O address and descriptions
This report lists each PLC module and its beginning and ending I/O address numbers. It scans your drawing set and returns all individual I/O connection points it finds. It includes up to five lines of description text and the connected wire number for each I/O point.
Toolbar: Main Electrical 2 
Command entry: AESCHEMATICREPORTSelect PLC I/O Address and Descriptions from the report list.
Extracts only the information for components with specific installation values. Indicate to process all components that carry part number values, components without an installation code, or only components marked with a location code that matches that entered in the edit box. Wild cards are supported.
After you click Named Installation, type the installation code in the box, or click List: Drawing or List: Project to select from a list of used installation codes. You can also create a report from multiple installation codes. AutoCAD Electrical automatically creates a comma-delimited list for the named installation search.
Extracts only the information for components with specific location values. Indicate to process all components that carry part number values, components without a location code, or only components marked with a location code that matches that entered in the edit box. For example, BOM report for components marked "OP STA 2." Wild cards are supported.
After you click Named Location, type the location code in the box, or click List: Drawing or List: Project to select from a list of used location codes. You can also create a report from multiple location codes. AutoCAD Electrical automatically creates a comma-delimited list for the named location search.
Specifies for AutoCAD Electrical to update the project database to include any out-of-date drawing files.
Changes the format of the extracted data. The dialog box lists the format files to select from.
This project-wide, stand-alone report lists all instances of terminals. Each entry includes information tied directly to the terminal such as terminal number, terminal strip number, and location code.
Toolbar: Main Electrical 2 
Command entry: AESCHEMATICREPORTSelect Terminal Numbers from the report list.
Specify whether to process the project or the active drawing.
Extracts only the information for components with specific installation values. Indicate to process all components that carry part number values, components without an installation code, or only components marked with a location code that matches that entered in the edit box. Wild cards are supported.
After you click Named Installation, type the installation code in the box, or click List: Drawing or List: Project to select from a list of used installation codes. You can also create a report from multiple installation codes. AutoCAD Electrical automatically creates a comma-delimited list for the named installation search.
Extracts only the information for components with specific location values. Indicate to process all components that carry part number values, components without a location code, or only components marked with a location code that matches that entered in the edit box. For example, BOM report for components marked "OP STA 2." Wild cards are supported.
After you click Named Location, type the location code in the box, or click List: Drawing or List: Project to select from a list of used location codes. You can also create a report from multiple location codes. AutoCAD Electrical automatically creates a comma-delimited list for the named location search.
Specifies for AutoCAD Electrical to update the project database to include any out-of-date drawing files.
Changes the format of the extracted data. The dialog box lists the format files to select from.
This project-wide, stand-alone report does a wire network extraction. It takes longer to generate, but the report includes wire number and wire layer name information.
Toolbar: Main Electrical 2 
Command entry: AESCHEMATICREPORTSelect Terminal Plan from the report list.
Specify whether to process the project, active drawing, or select components.
Extracts only the information for components with specific installation values. Indicate to process all components that carry part number values, components without an installation code, or only components marked with a location code that matches that entered in the edit box. Wild cards are supported.
After you click Named Installation, type the installation code in the box, or click List: Drawing or List: Project to select from a list of used installation codes. You can also create a report from multiple installation codes. AutoCAD Electrical automatically creates a comma-delimited list for the named installation search.
Extracts only the information for components with specific location values. Indicate to process all components that carry part number values, components without a location code, or only components marked with a location code that matches that entered in the edit box. For example, BOM report for components marked "OP STA 2." Wild cards are supported.
After you click Named Location, type the location code in the box, or click List: Drawing or List: Project to select from a list of used location codes. You can also create a report from multiple location codes. AutoCAD Electrical automatically creates a comma-delimited list for the named location search.
Lists drawings that appear to be out-of-date with the wire connection table of the project.
Specifies for AutoCAD Electrical to update the wire connection table to include any out-of-date drawing files.
Changes the format of the extracted data. The dialog box lists the format files to select from.
Schematic PLC modules used so far
For the PLC Modules Used So Far report, AutoCAD Electrical quickly scans the wiring diagram set. It returns in a few moments and displays the I/O modules it finds. Each entry shows the beginning and ending address of the module.
Toolbar: Main Electrical 2 
Command entry: AESCHEMATICREPORTSelect PLC Modules Used So Far from the report list.
Extracts only the information for components with specific installation values. Indicate to process all components that carry part number values, components without an installation code, or only components marked with a location code that matches that entered in the edit box. Wild-cards are supported.
After you click Named Installation, type the installation code in the box, or click List: Drawing or List: Project to select from a list of used installation codes. You can also create a report from multiple installation codes. AutoCAD Electrical automatically creates a comma-delimited list for the named installation search.
Extracts only the information for components with specific location values. Indicate to process all components that carry part number values, components without a location code, or only components marked with a location code that matches that entered in the edit box. For example, BOM report for components marked "OP STA 2." Wild cards are supported.
After you click Named Location, type the location code in the box, or click List: Drawing or List: Project to select from a list of used location codes. You can also create a report from multiple location codes. AutoCAD Electrical automatically creates a comma-delimited list for the named location search.
Specifies for AutoCAD Electrical to update the project database to include any out-of-date drawing files.
Changes the format of the extracted data. The dialog box lists the format files to select from.
This report lists wire markers/labels and can be used to create physical wire or cable labels.
Toolbar: Main Electrical 2 
Command entry: AESCHEMATICREPORTSelect Wire Label from the report list.
Specify whether to process the project, the active drawing, or selected wires.
Extracts only the information for components with specific installation values. Indicate to process all components that carry part number values, components without an installation code, or only components marked with a location code that matches that entered in the edit box. Wildcards are supported.
Once you pick Named Installation, type the installation code in the box or click List: Drawing or List: Project to select from a list of used installation codes. You can also create a report from multiple installation codes. AutoCAD Electrical automatically creates a comma-delimited list for the named installation search.
Extracts only the information for components with specific location values. Indicate to process all components that carry part number values, components without a location code, or only components marked with a location code that matches that entered in the edit box. For example, BOM report for components marked "OP STA 2". Wild-cards are supported.
Once you pick Named Location, type the location code in the box or click List: Drawing or List: Project to select from a list of used location codes. You can also create a report from multiple location codes. AutoCAD Electrical automatically creates a comma-delimited list for the named location search.
Lists drawings that appear to be out-of-date with the wire connection table of the project.
Specifies for AutoCAD Electrical to update the wire connection table to include any out-of-date drawing files.
Changes the format of the extracted data. The dialog box lists the format files to select from.
Location code selection for from/to reporting
When you select to run a Wire From/To report, AutoCAD Electrical extracts component, terminal, location code, and wire connection information from the selected drawings. This dialog box allows you to make your report’s “from” and “to” location selections. All the location codes AutoCAD Electrical found on the drawing set are listed on each side of this dialog box. Location “(??)” is also included in the list if AutoCAD Electrical found any component or stand-alone terminals that did not have an assigned location code.
Toolbar: Main Electrical 2 
Command entry: AESCHEMATICREPORTSelect Wire From/To from the report list. Specify whether to process the project, active drawing, or selected wires.
Select location codes from the left and right-hand lists to build the report’s from/to combinations shown in the middle of the dialog box. Click OK to display the report. AutoCAD Electrical quickly filters and formats the extracted data and presents it in the Report Generator dialog box. You can then save it to a text report file, a comma-delimited file to import into a spreadsheet or database program, or insert it on to a drawing in table format.