How to add your knowledge

Component Grounding Override <IvComponentGroundingOverride>

    Table of contents
    1. 1. Synopsis
    2. 2. Mixins
    3. 3. Parameters
    4. 4. Example 1

    Synopsis

    For an assembly controlled by a positional representation, suppression status, constraint values, grounding status and flexibility status can be overridden. Components with overrides are indicated in bold font, with the override value shown in parentheses. Values of the master positional representation can not be overridden. Any number of components can be grounded, even though typically only one component is grounded in an assembly. A grounded component has no degrees of freedom, and its position is fixed and independent from other components.

    Mixins

    IvComponentGroundingOverrideModifier

    IvPositionalOverrideMixin

    BaseInventorMixin

    Basepart

    Parameters

    Name Type Description
    componentOccurrence part Component occurrence that is being overridden.
    overrideValue boolean If True make the componentOccurrence grounded; if False it is not grounded.
    positionalRepresentation part Positional representation, override refers to.

    Example 1

    Child Name: Fixture_1
    Child Design: IvComponentGroundingOverride
    NameTypeSupplied
    componentOccurrence part NHA:self:
    overrideValue boolean True
    positionalRepresentation part NHA: