Specifying Default Fittings for a Duct Type

    Table of contents
    No headers
    • Revit MEP iconRevit MEP
    1. In the Project Browser, expand FamiliesDucts, and expand Oval Duct, Rectangular Duct, or Round Duct.
    2. Right-click a duct type, and click Properties.
    3. In the Type Properties dialog, under Type Parameters, under Mechanical, specify the following default fitting types:
      • Preferred Junction Type: Tee or Tap
      • Elbow
      • Tee
      • Tap
      • Cross
      • Transition
      • Multi Shape Transition Rect to Round
      • Multi Shape Transition Rect to Oval
      • Multi Shape Transition Oval to Round
      • Union