The following table describes each parameter contained on the Path Reinforcement Properties palette.
| Name | Description |
|---|---|
| Construction | |
| Layout Rule | Specifies the type of rebar layout. Select either Maximum Spacing or Fixed Number. See Placing Rebar Sets. |
| Additional Offset | Specifies an additional offset from the rebar cover. This allows placing multiple rebar elements together in different path reinforcement layers. |
| Graphics | |
| View Visibility States | Accesses rebar view visibility states. Click Edit to either view or edit the state. See Rebar View Visibility States. NoteThis parameter is only available when hosting rebar in path reinforcement. See Modifying Reinforcement Settings. |
| Structural | |
| Reinforcement Volume | Calculates and displays reinforcement volume (read-only). |
| Layers | |
| Face | Specifies the face justification, either top or bottom. |
| Bar Spacing | Specifies the spacing for rebar placed in the major direction. This parameter is only accessible with the Maximum Spacing Layout Rule. |
| Number of Bars | Specifies the number of rebar instances within the reinforcement. You can access this parameter with the Fixed Number Layout Rule. |
| Primary Bar - Type | Specifies the bar type. |
| Primary Bar - Length | Specifies the length of the rebar. |
| Primary Bar - Start Hook Type | Specifies the type of hook (either Standard or Stirrup/Tie) and the angle for the start of the path reinforcement. |
| Primary Bar - End Hook Type | Specifies the type of hook (either Standard or Stirrup/Tie) and the angle for the end of the path reinforcement. |
| Primary Bar - Hook Orientation | Specifies the orientation of the rebar hook, either up or down. |
| Alternating Bars | When selected, enables alternate bar type. |
| Alternating Bar - Type | Specifies the bar type. Selecting the Alternating Bars parameter enables this parameter. |
| Alternating Bar - Length | Specifies the length of the rebar. Selecting the Alternating Bars parameter enables this parameter. |
| Alternating Bar - Offset | Specifies the offset distance from the primary bar. Selecting the Alternating Bars parameter enables this parameter. |
| Alternating Bar - Start Hook Type | Specifies the type of hook (either Standard or Stirrup/Tie) and the angle for the start of the path reinforcement. Selecting the Alternating Bars parameter enables this parameter. |
| Alternating Bar - End Hook Type | Specifies the type of hook (either Standard or Stirrup/Tie) and the angle for the end of the path reinforcement. Selecting the Alternating Bars parameter enables this parameter. |
| Alternating Bar - Hook Orientation | Specifies the orientation of the rebar hook, either up or down. Selecting the Alternating Bars parameter enables this parameter. |
| Identity Data | |
| Comments | User comments |
| Mark | A label used, for example, as a shop mark. This value must be unique for each element in a project. Revit warns you if the value is in use, but allows you to continue using it. You can see the warning using the Review Warnings command. See Reviewing Warning Messages. |
| Phasing | |
| Phase Created | Indicates the creation phase of the host element. See Project Phasing. |
| Phase Demolished | Indicates the demolition phase of the host element. See Project Phasing. |