Switch to the other controller by

    Table of contents
    No headers

    For the Co-injection molding process, this specifies when to switch from Controller A to Controller B, or from Controller B back to Controller A. Controller A controls Material A (usually the skin material) and Controller B controls Material B (usually the core material).

    When the cavity volume reaches the specified percentage filled, control switches from the active controller to the other controller.