No headersThe Microchip Options tab of the Reactive Molding solver parameters (3D) dialog is used to specify values for analysis related inputs for a 3D Microchip Encapsulation analysis.
| This option is used to select the type of Stress analysis to run to predict paddle shift/wire sweep. |
| If the analysis sequence includes wire sweep and/or paddle shift simulation, this option is used to specify which solver will be used to perform this simulation. |
| This option is used to define a lower bound for the temperature value when calculating the viscosity of the material. When the predicted temperature of the melt is lower than the cut-off value, then the viscosity is calculated at this viscosity cut-off temperature. NoteThis option is specifically intended for 3D reactive analyses that exhibit convergence problems, typically for materials with a low melt temperature. These convergence problems may be able to be resolved by setting the viscosity cut-off temperature to somewhat higher than the melt temperature. |
| When the selected analysis sequence includes Wire Sweep, this option is used to specify whether the analysis will account for the effects of wires on flow. - The default setting is .
- Change the setting to to include the effects of wires on flow and effects of adjacent wires on the drag force.
NoteThis option is available only when the wire sweep calculation is performed in Autodesk Simulation Moldflow Insight. NoteThe Wire Sweep Detail analysis always includes the effects of wires on flow. Therefore, the option setting has no effect on results when the analysis sequence includes Wire Sweep Detail. |
| When the selected analysis sequence includes Wire Sweep, this option is used to define the distance between pairs of adjacent wires (after wire deformation) at which the wires are considered to be too close together. The clearance distance is measured between the surfaces of adjacent wires. - The default value is 0, which indicates that adjacent wires can touch.
- Specify a value greater than zero if you want more clearance between adjacent wires.
NoteThis option is available only when the wire sweep calculation is performed in Autodesk Simulation Moldflow Insight. |
| This option specifies whether the part insert and core temperatures are set to a fixed value, or calculated by the Fill+Pack analysis. |
To specify values for these options to be used in the current study, double-click
in the Study Tasks pane, or click
() to open the Process Settings Wizard. Click to display the Profile Settings page; click ; click in the Solver parameters area; and click the Microchip Options tab.
To view or change default settings for these options, click
(); from the Properties list, select , and then from the Description table, select ; click ; and click the Microchip Options tab.