Solver message 98303

    Table of contents
    1. 1. Message text
    2. 2. Explanation
    3. 3. Resolution

    Message text

    ** WARNING 98303 ** The polymer PVT data is incorrect. Unable to perform residual stress analysis.

    Explanation

    This error occurs when the solid density is less than the density calculated using the Tait 2-Domain pvT model at the transition temperature and zero pressure.

    Resolution

    • Edit the current material, select the pvT Properties tab and change the value for the Solid density.
    • Edit the current material, select the pvT Properties tab and change values for the coefficients for the Tait 2-Domain pvT model.
    • Select a different material.