Simulation Moldflow

Community Scoring

Was this page helpful?

Tag Tags0

This page has no tags

Page statistics

875 views1 edit(s)1983 characters(s) Page last modified 04:00, 5 Jun 2012 by contentconnector
How to add your knowledge

Solver message 98319

    Table of contents
    1. 1. Message text
    2. 2. Explanation
    3. 3. Resolution

    Message text

    ** WARNING 98319 ** Specific heat data has not been specified for the second polymer. Continuing analysis without co-injection.

    Explanation

    This warning message means that there is no specific heat data available for the second material (material B) in the Co-injection analysis.

    Resolution

    • Edit the second material and enter a value for the specific heat.
    • Select a different material.
    • If the material is from the Autodesk Simulation Moldflow materials database, contact Technical Support.