Solver message 98329

    Table of contents
    1. 1. Message text
    2. 2. Explanation
    3. 3. Resolution

    Message text

    ** WARNING 98329 ** Thermal conductivity data has not been specified for the second polymer. Continuing analysis without co-injection.

    Explanation

    This warning message means that there is no thermal conductivity data available for the second material (material B) in the Co-injection analysis.

    Resolution

    • Edit the second material and enter a value for the thermal conductivity.
    • Select a different material.
    • If the material is from the Autodesk Simulation Moldflow materials database, contact Technical Support.