Solver message 98608

    Table of contents
    1. 1. Message text
    2. 2. Explanation
    3. 3. Resolution

    Message text

    ** WARNING 98608 ** The maximum machine injection rate value in the injection unit properties of the selected injection molding machine is outside the expected range. Check the injection molding machine settings and run the analysis again.

    Explanation

    The maximum machine injection rate specified for the analysis in the Analysis File:Simulation_Moldflow/enu/2013/Help/Adviser/2076-Error_an2076/2150-Solver_m2150/ac.menuaro.gif Process Settings Wizard... File:Simulation_Moldflow/enu/2013/Help/Adviser/2076-Error_an2076/2150-Solver_m2150/ac.menuaro.gif Advanced options... is outside the expected range, meaning it is either too small or large.

    Resolution

    • Under the Injection molding machine settings, click Edit, select the Injection Unit tab, and change the value for the Maximum machine injection rate.
    • Under the Injection molding machine settings, click Select and choose a different machine.