Solver message 2002023

    Table of contents
    1. 1. Message text
    2. 2. Explanation
    3. 3. Resolution

    Message text

    ** WARNING 2002023 ** Core-shift analysis is off. Ignoring core elements.

    Explanation

    The Perform core shift analysis option in Solver parameters is off. Core (3D) elements will be ignored.

    Resolution

    If you wish to run a core shift analysis, select Analysis File:Simulation_Moldflow/enu/2013/Help/Adviser/2076-Error_an2076/2153-Solver_m2153/ac.menuaro.gif Process Settings Wizard, click Advanced options... , then click the Edit... button associated with Solver parameters. Select the Core Shift tab, then select the Perform core shift analysis option.