Simulation Moldflow

Community Scoring

Was this page helpful?

Tag Tags0

This page has no tags

Page statistics

875 views1 edit(s)2906 characters(s) Page last modified 04:02, 5 Jun 2012 by contentconnector
How to add your knowledge

Solver message 98693

    Table of contents
    1. 1. Message text
    2. 2. Explanation
    3. 3. Resolution

    Message text

    ** WARNING 98693 ** The maximum machine injection pressure value in the hydraulic unit properties of the selected injection molding machine is outside the expected range so a default value of injection pressure value will be used instead. Check the injection molding machine settings and run the analysis again.

    Explanation

    The value specified for Maximum machine injection pressure in the Process Settings Wizard, Advanced options... is outside the expected range, meaning that it is either too small or too large. The analysis will use the default value for the selected injection molding machine.

    Resolution

    • Change the Maximum machine injection pressure in the Hydraulic Unit tab of the Injection modling machine dialog.
    • Select a different injection molding machine, by clicking Select... adjacent to Injection molding machine.
    • If the injection molding machine is from the Autodesk Simulation Moldflow database, contact Technical Support.