Solver message 98843

    Table of contents
    1. 1. Message text
    2. 2. Explanation
    3. 3. Resolution

    Message text

    ** WARNING 98843 ** The heat transfer coefficient between pot and pellet (bottom) value ( heat transfer coefficient value ) in the advanced options -> solver parameters -> mesh/boundary settings is outside the expected range and should be between 10 and 25000. Please check the solver parameter settings and, if necessary, rerun the analysis.

    Explanation

    The heat transfer coefficient between pot and pellet (bottom) is outside the expected range, meaning that it is either too small or too large.

    Resolution

    In the Process Settings Wizard, navigate to the Profile Settings page and click Advanced options.... Click the Edit... button associated with Solver parameters and change the entry for Heat transfer coefficient between pot and pellet (bottom) to an appropriate value. Then re-run the analysis.