Solver message 99090

    Table of contents
    1. 1. Message text
    2. 2. Explanation
    3. 3. Resolution

    Message text

    ** ERROR 99090 ** The automatic determination of fill time failed. Specify the filling time manually in the process settings and run the analysis again.

    Explanation

    The fill time could not be determined automatically during the fill/pack analysis.

    Resolution

    Specify an Injection time manually in the process settings.