Solver message 99115

    Table of contents
    1. 1. Message text
    2. 2. Explanation
    3. 3. Resolution

    Message text

    ** ERROR 99115 ** The number of profiled intermediate results in the filling phase is an invalid value. Values allowed are 0, 4, 8, 12 and 20. Enter an appropriate value in the Process Settings Wizard and re-run the analysis.

    Explanation

    The number of profiled intermediate results in the filling phase is invalid. Values allowed are 0, 4, 8, 12 and 20.

    Resolution

    Click Analysis File:Simulation_Moldflow/enu/2013/Help/Adviser/2076-Error_an2076/2258-Solver_m2258/ac.menuaro.gif Process Settings Wizard and navigate to the Profile Settings dialog. Click Advanced options..., then click the Edit.... button associated with Solver parameters. Select the Intermediate Output tab and change the output settings for the Filling phase.