Solver message 99120

    Table of contents
    1. 1. Message text
    2. 2. Explanation
    3. 3. Resolution

    Message text

    ** ERROR 99120 ** The number of intermediate results in the packing phase is an invalid value. Values allowed are 0, 4, 8, 12, 20, 40 and 100. Enter an appropriate value in the process settings and re-run the analysis.

    Explanation

    The number of intermediate results in the packing phase is invalid. Values allowed are 0, 4, 8, 12, 20, 40 and 100.

    Resolution

    This value is set in the Process Settings Wizard. Click Analysis File:Simulation_Moldflow/enu/2013/Help/Adviser/2076-Error_an2076/2259-Solver_m2259/ac.menuaro.gif Process Settings Wizard and navigate to the Profile Settings dialog. Click Advanced options..., then click on the Edit.... button associated with Solver parameters. Select the Intermediate Output tab and change the output selection for Packing phase.