** ERROR 99323 ** The thermal conductivity of the selected material is less than or equal to zero. Typical value: 0.1 W/m-C. Check the material data and run the analysis again.
Explanation
The polymer thermal conductivity is outside the expected range.
Resolution
Edit the current material and change the thermal conductivity. Typical thermal conductivity values are around 0.1 W/m-C.
Select a different material.
If the material is from the Autodesk Simulation Moldflow materials database, contact Technical Support.