Simulation Moldflow

Community Scoring

Was this page helpful?

Tag Tags0

This page has no tags

Page statistics

865 views2 edit(s)2385 characters(s) Page last modified 09:25, 5 Jun 2012 by contentconnector
How to add your knowledge

Solver message 99662

    Table of contents
    1. 1. Message text
    2. 2. Explanation
    3. 3. Resolution

    Message text

    ** ERROR 99662 ** The velocity/pressure switch-over by pressure control point value is zero or negative. Check the process settings and run the analysis again.

    Explanation

    The value for velocity/pressure switch-over by pressure control point is zero or negative. If the pressure in the cavity or runner system exceeds this value, the process switches from flow rate (ram speed) control to pack/hold pressure control.

    Resolution

    Click Analysis File:Simulation_Moldflow/enu/2013/Help/Adviser/2076-Error_an2076/2384-Solver_m2384/ac.menuaro.gif Process Settings Wizard then click the Edit settings... button associated with Velocity/pressure switch-over. Enter a positive value for pressure in the Pressure Control Point Settings dialog.