Solver message 1300580

    Table of contents
    1. 1. Message text
    2. 2. Explanation
    3. 3. Resolution

    Message text

    ** ERROR 1300580 ** Maximum Stroke of Machine Exceeded Suggested Action(s): Choose an Injection Molding Machine with Larger Injection Capacity Use a Larger Diameter Screw

    Explanation

    The Process Optimization analysis cannot optimize the injection profile because the injection stroke required to fill the part is greater than the Maximum machine injection stroke.

    Resolution

    Select a higher capacity injection molding machine, or select Analysis File:Simulation_Moldflow/enu/2013/Help/Adviser/2076-Error_an2076/2628-Solver_m2628/ac.menuaro.gif Process Settings Wizard, click Advanced options..., then click the Edit... button associated with Process controller. Click the Edit profile... button associated with the Filling control setting and edit the Stroke volume settings to increase the Machine screw diameter.