Solver message 1300640

    Table of contents
    1. 1. Message text
    2. 2. Explanation
    3. 3. Resolution

    Message text

    ** WARNING 1300640 ** Since negative volumetric shrinkage value is allowed and sink mark weight is high(>=5), optimum processing condition obtained with this analysis may lead to negative volumetric shrinkage result in subsequent Flow analysis.

    Explanation

    Since negative volumetric shrinkage value is allowed and sink mark weight is high(>=5), optimum processing conditions obtained with this analysis may cause a negative volumetric shrinkage result in a subsequent Fill+Pack analysis.

    Resolution

    Select Analysis File:Simulation_Moldflow/enu/2013/Help/Adviser/2076-Error_an2076/2634-Solver_m2634/ac.menuaro.gif Process Settings Wizard, click Next >, and either input a smaller sink mark criterion weighting, or click Advanced options and uncheck the Negative volumetric shrinkage value is allowed box.