Solver message 1300650

    Table of contents
    1. 1. Message text
    2. 2. Explanation
    3. 3. Resolution

    Message text

    ** WARNING 1300650 ** Negative volumetric shrinkage value can be observed in subsequent Flow analysis running with optimum processing condition obtained with this analysis.

    Explanation

    Since negative volumetric shrinkage value is allowed and sink mark weight is high(>=5), optimum processing conditions obtained with this analysis may cause a negative volumetric shrinkage result in a subsequent Fill+Pack analysis.

    Resolution

    Select Analysis File:Simulation_Moldflow/enu/2013/Help/Adviser/2076-Error_an2076/2635-Solver_m2635/ac.menuaro.gif Process Settings Wizard, click Next > and either input a smaller sink mark criterion weighting, or click Advanced options and uncheck the Negative volumetric shrinkage value is allowed box.