Solver message 200886

    Table of contents
    1. 1. Message text
    2. 2. Explanation
    3. 3. Resolution

    Message text

    ** ERROR 200886 ** Stiffness matrix of element element number is ill-conditioned.

    Explanation

    A solution error (zero diagonal term) occurred in the Warp analysis for a section of the model.

    Resolution

    • Edit the mechanical properties for the current material.
    • Simplify the model geometry and remove text, fillets and other features which do not affect warpage.
    • Check for mesh defects using the diagnostics tools provided in the Mesh menu. Plot the pvT and viscosity plots for the material. Check the process settings for the analysis.
    • If the problem persists, contact Technical Support.