Simulation Moldflow

Community Scoring

Was this page helpful?

Tag Tags0

This page has no tags

Page statistics

870 views2 edit(s)2198 characters(s) Page last modified 09:46, 5 Jun 2012 by contentconnector
How to add your knowledge

Solver message 221068

    Table of contents
    1. 1. Message text
    2. 2. Explanation
    3. 3. Resolution

    Message text

    ** ERROR 221068 ** Disconnected node node number.

    Explanation

    All nodes in the analysis must be associated with valid elements. Disconnected nodes in the model are generally ignored, but this error indicates that a node which is not connected to valid elements has somehow been included in the analysis mesh.

    Resolution

    Locate the node specified in the message using Modeling File:Simulation_Moldflow/enu/2013/Help/Adviser/2076-Error_an2076/2922-Solver_m2922/ac.menuaro.gif Query Entities, and check that the mesh in that region is valid. Remesh the geometry starting from a better quality Dual Domain mesh (less high aspect ratio triangles). If the problem persists, contact Technical Support.