Solver message 221098

    Table of contents
    1. 1. Message text
    2. 2. Explanation
    3. 3. Resolution

    Message text

    ** ERROR 221098 ** Uniform flowrate distribution option is not allowed for beam runner solution.

    Explanation

    An error was detected with the filling control options at the injection location. The most likely cause is that the defaults.udm file in the data/dat directory where Autodesk Simulation Moldflow Insight was installed has become corrupted.

    Resolution

    Delete any local copies of the *_defaults.udm file in the My Documents\My ASMI xxxx Projects\udm directory. Reinstall the software. Then, re-import the geometry into Autodesk Simulation Moldflow Insight from the original CAD model.