Solver message 221144

    Table of contents
    1. 1. Message text
    2. 2. Explanation
    3. 3. Resolution

    Message text

    ** ERROR 221144 ** The specified gas profile is based on incremental time values. Change the times to absolute and run the analysis again.

    Explanation

    You have entered a gas profile for the Gas-assisted injection controller of a gas entrance, based on incremental times. The profile data must be entered using absolute times, from the start of gas injection.

    Resolution

    Right-click on the gas entrance and select Properties. Click Edit, then click Edit controller settings and change the time values to absolute times from the start of gas injection.