Solver message 223001

    Table of contents
    1. 1. Message text
    2. 2. Explanation
    3. 3. Resolution

    Message text

    ** WARNING 223001 ** Node node number is connected to only one other inlet node.

    Explanation

    If multiple injection locations are selected on a tetrahedral model, then this message warns that two injection locations are not connected to the main patch of injection locations. This might be an error in injection location selection.

    Resolution

    Check that all injection locations have been applied appropriately.