Solver message 301775

    Table of contents
    1. 1. Message text
    2. 2. Explanation
    3. 3. Resolution

    Message text

    ** WARNING 301775 ** There is no value specified for the fiber coefficient of interaction (Ci) scalar. Check the process settings and run the analysis again.

    Explanation

    There is no option specified for the fiber coefficient of interaction (Ci) scalar. Check Process Settings Wizard-Fiber Parameters.

    Resolution

    Go to Analysis File:Simulation_Moldflow/enu/2013/Help/Adviser/2076-Error_an2076/3109-Solver_m3109/ac.menuaro.gif Process Settings Wizard. Make sure that Fiber orientation analysis if fiber material is selected, click Fiber parameters, and set the Coefficient of interaction (Ci) to Auto-calculated scalar value.