Solver message 304700

    Table of contents
    1. 1. Message text
    2. 2. Explanation
    3. 3. Resolution

    Message text

    ** WARNING 304700 ** Altogether %d part elements with no flow path to injection were found. See above list of elements.

    Explanation

    The input study file for this analysis contains part elements (up to 20 listed) which have no flow path to a polymer injection location. Flow path here means a sequence of nodes joined by part elements. The absence of a flow path means that these elements cannot fill. This is presumed to be unintentional so analysis has been stopped.

    Resolution

    Examine the elements in the GUI. Use Modeling File:Simulation_Moldflow/enu/2013/Help/Adviser/2076-Error_an2076/3245-Solver_m3245/ac.menuaro.gif Query Entities to locate the elements. It may be that the elements have been designated as 'part' instead of 'insert'. If so, correct the properties of these elements and resubmit the analysis. Another possibility is that a multi-cavity part has been meshed but no runner system has been connected to one or more of these cavities. If the elements are not required, delete and then run Mesh File:Simulation_Moldflow/enu/2013/Help/Adviser/2076-Error_an2076/3245-Solver_m3245/ac.menuaro.gif Mesh Tool File:Simulation_Moldflow/enu/2013/Help/Adviser/2076-Error_an2076/3245-Solver_m3245/ac.menuaro.gif Nodal Tools File:Simulation_Moldflow/enu/2013/Help/Adviser/2076-Error_an2076/3245-Solver_m3245/ac.menuaro.gif Purge Nodes to remove any associated nodes that are no longer required.