Solver message 700960

    Table of contents
    1. 1. Message text
    2. 2. Explanation
    3. 3. Resolution

    Message text

    ** ERROR 700960 ** Integration collection point is on the beam element surface. The surface of the beam element is possibly touching or intersecting another element

    Explanation

    The Cool solver has detected that a beam element, for example a runner or cooling channel element, is touching or intersecting a triangular element, for example a part surface or part insert element.

    Resolution

    Check the model for contacting or intersecting beam and triangular elements and correct any problems.