Solver message 702300

    Table of contents
    1. 1. Message text
    2. 2. Explanation
    3. 3. Resolution

    Message text

    ** WARNING 702300 ** Automatic target thickness convergence failure. Using thickness value.

    Explanation

    When performing a Cool analysis on a Midplane or Dual Domain model and the cooling time is set to automatic in the process settings, the solver first calculates a target frozen thickness of the part taking the frozen percentage as well as part thickness into account. In this case it is unable to calculate an accurate thickness and continues with the thickness shown in the message. The model may have large variations in thickness that is causing this problem.

    Resolution

    Check the results carefully at the end of the analysis. Select Mesh File:Simulation_Moldflow/enu/2013/Help/Adviser/2076-Error_an2076/3424-Solver_m3424/ac.menuaro.gif Mesh Diagnostics File:Simulation_Moldflow/enu/2013/Help/Adviser/2076-Error_an2076/3424-Solver_m3424/ac.menuaro.gif Thickness Diagnostic and check that the assigned or automatically determined thickness values in the part are correct.