Solver message 702340

    Table of contents
    1. 1. Message text
    2. 2. Explanation
    3. 3. Resolution

    Message text

    ** ERROR 702340 ** Node node number is only connected to one baffle element. Baffles need to be modeled with elements representing both the upward section and the downward section in order to obtain unique heat transfer coefficents for both sections.

    Explanation

    The cooling network solver has encountered a modeling error for the baffle located at the indicated node.

    Resolution

    Model the baffle with one curve of type Baffle to represent the upward section and another curve of type Baffle to represent the downward section. The nodes at the bottom of the baffle can either be displaced somewhat or coincident.