This object is not available in the repository.
The Cool summary page lists the key results of the Cool analysis.
The Circuit coolant temperature result shows the temperature of the coolant inside the cooling circuit.
The Circuit flow rate result shows the flow rate of the coolant inside the cooling circuit.
The Circuit pressure result is generated from a Cool analysis to show the distribution of pressure along a cooling circuit, averaged over the cycle.
The Circuit Reynolds number result shows the Reynolds number of the coolant in the cooling circuit.
The Cooling quality result shows you where heat tends to stay in a part due to its shape, thickness, and the effects of existing cooling circuits.
The Cooling time variance result shows the difference between the time it takes for polymer to freeze in any region of the part and the average time it takes to freeze in the entire part.
The Temperature, part result shows the average temperature at the part boundary, which is at the part side of the part/mold interface, over the duration of the cycle.
The Temperature variance result highlights areas where the part geometry and the cooling system will cause the surface temperature to be different from the average part temperature, which is taken at the end of the cycle.
The Time to reach ejection temperature, part result that is produced by a Cool analysis shows the time required to reach the ejection temperature, which is measured from the start of the cycle.