Solver message 97625

    Table of contents
    1. 1. Message text
    2. 2. Explanation
    3. 3. Resolution

    Message text

    ** WARNING 97625 ** The Closure approximation model has been changed (%2d) from the one (%2d) used in the CRIMS correlation.

    Explanation

    If the Closure approximation model is changed to a different model from the one used in the CRIMS correlation, the warpage results based on the CRIMS model may not be reliable.

    Resolution

    The Closure approximation model used in the CRIMS correlation should be used if the CRIMS shrinkage model is used. That is, the default Closure approximation model should be used in the Composite Property Calculation Options dialog, which is accessed by clicking Fiber parameters... in the Process Settings Wizard, and clicking Composite property calculation options....