Solver message 98684

    Table of contents
    1. 1. Message text
    2. 2. Explanation
    3. 3. Resolution

    Message text

    ** WARNING 98684 ** The total volume to be filled is more that 80%% of the maximum machine injection volume calculated from the maximum machine injection stroke and machine screw diameter values for the currently selected injection molding machine. The capacity of the selected injection molding machine may not be sufficient to fill the part.

    Explanation

    The capacity of the selected injection molding machine may not be sufficient to fill the part, when considering the compressibility of the melt in the cavity.

    Resolution

    • Check that the model was imported with the correct units.
    • Click Analysis File:Simulation_Moldflow/enu/2013/Help/Adviser/2076-Error_an2076/2191-Solver_m2191/ac.menuaro.gif Process Settings Wizard... File:Simulation_Moldflow/enu/2013/Help/Adviser/2076-Error_an2076/2191-Solver_m2191/ac.menuaro.gif Advanced options... Next to the Injection molding machine, click Edit, select the Injection Unit tab and increase the stroke volume.
    • Select a different injection molding machine.