Solver message 104011

    Table of contents
    1. 1. Message text
    2. 2. Explanation
    3. 3. Resolution

    Message text

    ** WARNING 104011 ** There is no valid strain data available for this material. Uncorrected residual stress shrinkage model will be used.

    Explanation

    The selected shrinkage model for the current material is Residual strain, however, there are no model coefficients data available for that shrinkage model, so the Uncorrected Residual Stress model, which does not require shrinkage testing of the material, will be used.

    Resolution

    • Select a different material.
    • Select a different shrinkage model.
    • Contact Autodesk Moldflow Plastics Labs for shrinkage data for the current material.