Solver message 99313

    Table of contents
    1. 1. Message text
    2. 2. Explanation
    3. 3. Resolution

    Message text

    ** ERROR 99313 ** The specific heat for the current material is less than or equal to zero. Typical value: 1000 J/kg C. Check the material data and run the analysis again.

    Explanation

    The polymer specific heat data is less than or equal to zero.

    Resolution

    • Edit the current material and enter a positive specific heat.
    • Select a different material.
    • If the material is from the Autodesk Simulation Moldflow materials database, contact Technical Support.