Simulation Moldflow

Community Scoring

Was this page helpful?

Tag Tags0

This page has no tags

Page statistics

867 views1 edit(s)1941 characters(s) Page last modified 04:06, 5 Jun 2012 by contentconnector
How to add your knowledge

Solver message 99318

    Table of contents
    1. 1. Message text
    2. 2. Explanation
    3. 3. Resolution

    Message text

    ** ERROR 99318 ** The specific heat for the second material is less than or equal to zero. Typical value: 1000 J/kg C. Check the material data and run the analysis again.

    Explanation

    The second polymer specific heat is less than or equal to zero.

    Resolution

    • Edit the second material and enter a positive specific heat.
    • Select a different material.
    • If the material is from the Autodesk Simulation Moldflow materials database, contact Technical Support.