Solver message 99361

    Table of contents
    1. 1. Message text
    2. 2. Explanation
    3. 3. Resolution

    Message text

    ** ERROR 99361 ** The fiber or filler mechanical property data is not consistent. The shear modulus should follow the following relation G12 = E1 / 2*(1+v12) In this isotropic set: E1 = value. E2 = value. v12 = value. v23 = value. G12 = value. Update the mechanical properties from latest database or make sure the set follows the above relation.

    Explanation

    The fiber or filler mechanical property data is not consistent.

    Resolution

    • Edit the current material and change the fiber/filler content.
    • Edit the fiber/filler and change its mechanical properties.
    • Select a different material.
    • If the material is from the Autodesk Simulation Moldflow materials database, contact Technical Support.