Solver message 99812

    Table of contents
    1. 1. Message text
    2. 2. Explanation
    3. 3. Resolution

    Message text

    ** ERROR 99812 ** Matrix is machine singular.

    Explanation

    A solution error occurred during the analysis.

    Resolution

    • Check the model geometry for very fine details such as text and fillets.
    • Check the model geometry for defects.
    • Plot pvT and viscosity plots for the current material.
    • Check the process settings.