Solver message 1300560

    Table of contents
    1. 1. Message text
    2. 2. Explanation
    3. 3. Resolution

    Message text

    ** ERROR 1300560 ** Insufficient injection capacity Suggested Action(s): Choose an Injection Molding Machine with Larger Injection Capacity Review Gate Location and/or Number of Gates Review Wall Thickness Increase Melt Temperature Increase Mold Temperature Increase Velocity Phase Flow Rate Upper Limit

    Explanation

    The Process Optimization analysis cannot optimize the injection profile because the pressure required to fill the part is higher than the Maximum machine injection pressure value. This value is found in the Hydraulic Unit properties for the current injection molding machine.

    Resolution

    Select a different injection molding machine, change the number or location of the gates, or adjust the Hydraulic Unit properties for the current machine. To do this, select Analysis File:Simulation_Moldflow/enu/2013/Help/Adviser/2076-Error_an2076/2626-Solver_m2626/ac.menuaro.gif Process Settings Wizard, click Advanced options... and click the Edit... button associated with Injection molding machine. Select the Hydraulic Unit tab and edit the value for Maximum machine injection pressure.