Solver message 1600092

    Table of contents
    1. 1. Message text
    2. 2. Explanation
    3. 3. Resolution

    Message text

    ** WARNING 1600092 ** The melt temperature range must be above the transition temperature of the material.

    Explanation

    The specified Delta (+/-) value for the Melt temperature option in the DOE settings, when applied to the Melt temperature value in the flow settings, gives a lower limit melt temperature value that is below the temperature at which the polymer will cease to flow (transition temperature).

    Resolution

    • Increase the melt temperature.
    • Decrease the melt temperature delta.