Solver message 1714130

    Table of contents
    1. 1. Message text
    2. 2. Explanation
    3. 3. Resolution

    Message text

    ** WARNING 1714130 ** The CRYSTALLINITY term in the PERPENDICULAR strain model had values which were too LOW in %5.1f%% of part elements (volume fraction). The lower limit has been used for these elements.

    Explanation

    The calculated crystallization related contribution to the predicted perpendicular shrinkage within the part exceeded the measured limits obtained under the range of process conditions considered in the shrinkage testing of the material.

    Resolution

    If the percentage part volume value is high, then the results of the Shrink analysis may not be reliable because the process conditions used in this study are significantly different to those considered in the shrinkage testing.