Solver message 201335

    Table of contents
    1. 1. Message text
    2. 2. Explanation
    3. 3. Resolution

    Message text

    ** WARNING 201335 ** Warpage analysis is a "buckling" or "frequency" analysis. No information will be transferred from the warpage to the stress analysis.

    Explanation

    You have selected an analysis sequence where a Stress analysis follows a Warp analysis. The predicted part deflections from the Warp analysis, and the predicted residual stresses in the part, can only be used as input for the Stress analysis if a large deflection Warp analysis was run. The Stress analysis was performed on the original part geometry.

    Resolution

    If you would like to consider the initial displacement and residual stress inputs from a Warp analysis, select Large Deflection analysis on the Warp Settings page of the Process Settings Wizard and rerun the analysis.