Solver message 201350

    Table of contents
    1. 1. Message text
    2. 2. Explanation
    3. 3. Resolution

    Message text

    ** WARNING 201350 ** Thermal loading analysis does not consider initial displacement and residual stress inputs from Warp analysis.

    Explanation

    You have selected an analysis sequence where a Stress analysis follows a Warp analysis. The predicted part deflections from the Warp analysis, and the predicted residual stresses in the part, can only be used as input for the Stress analysis if no thermal loads have been applied to the part and a large deflection Warp analysis was run. The Stress analysis was performed on the original part geometry.

    Resolution

    None required. The stress solver does not currently support this loading and analysis sequence scenario.