Solver message 220020

    Table of contents
    1. 1. Message text
    2. 2. Explanation
    3. 3. Resolution

    Message text

    ** ERROR 220020 ** Velocity/pressure switch-over time cannot be after rescale time.

    Explanation

    The velocity (filling) control profile has been scaled to match an absolute duration time, however the switch-over from velocity to pressure control (packing) has been specified by a time value which is greater than the filling phase duration. Therefore, switch-over to pressure control cannot occur before the cavity is 100% filled.

    Resolution

    Select Analysis File:Simulation_Moldflow/enu/2013/Help/Adviser/2076-Error_an2076/2856-Solver_m2856/ac.menuaro.gif Process Settings Wizard and set an earlier Velocity/pressure switch-over time, or a longer velocity profile duration under Filling Control.