** ERROR 223028 ** Occurrence number values are corrupt.
Explanation
The Occurrence number setting for one or more elements in the model is not specified.
Resolution
Select Mesh Mesh Diagnostics Occurrence Number Diagnostic and display the occurrence number assignments in the model. To correct the occurrence of an element, right-click on the element and select Properties, then enter the new value in the Properties dialog.