Solver message 223028

    Table of contents
    1. 1. Message text
    2. 2. Explanation
    3. 3. Resolution

    Message text

    ** ERROR 223028 ** Occurrence number values are corrupt.

    Explanation

    The Occurrence number setting for one or more elements in the model is not specified.

    Resolution

    Select Mesh File:Simulation_Moldflow/enu/2013/Help/Adviser/2076-Error_an2076/2977-Solver_m2977/ac.menuaro.gif Mesh Diagnostics File:Simulation_Moldflow/enu/2013/Help/Adviser/2076-Error_an2076/2977-Solver_m2977/ac.menuaro.gif Occurrence Number Diagnostic and display the occurrence number assignments in the model. To correct the occurrence of an element, right-click on the element and select Properties, then enter the new value in the Properties dialog.