Solver message 223054

    Table of contents
    1. 1. Message text
    2. 2. Explanation
    3. 3. Resolution

    Message text

    ** ERROR 223054 ** No injection location on part found.

    Explanation

    For a Fill+Pack analysis to be performed, at least one injection location must be specified. The injection location must be of the correct type. For example, a thermoplastics Fill+Pack analysis must be set using Analysis File:Simulation_Moldflow/enu/2013/Help/Adviser/2076-Error_an2076/2986-Solver_m2986/ac.menuaro.gif Set Injection Locations. For an Overmolding Fill+Pack analysis you need to set the Overmolding injection location for the second molding component using Analysis File:Simulation_Moldflow/enu/2013/Help/Adviser/2076-Error_an2076/2986-Solver_m2986/ac.menuaro.gif Set Overmolding Injection Locations. This error will occur if the process type has been changed after the injection location was specified.

    Resolution

    • Specify an injection location.
    • Delete existing injection locations and create them again.