Solver message 301930

    Table of contents
    1. 1. Message text
    2. 2. Explanation
    3. 3. Resolution

    Message text

    ** ERROR 301930 ** An invalid valve gate configuration has been specified. With this configuration the valve gates will not open and the part will never fill.

    Explanation

    An invalid valve gate configuration has been specified. With this configuration the valve gates will not open and the part will never fill. An example of an invalid configuration is when all paths to the part are controlled by valve gates that open up with the flow front option.

    Resolution

    Reassess all the valve gates in the model and make sure that there is a path for the part to fill initially. Check the initial status of the valve gates and ensure that not all the gates are controlled with the flow front option