Solver message 302137

    Table of contents
    1. 1. Explanation
    2. 2. Resolution

    Explanation

    There is not enough memory available to analyze this model using the AMG matrix solver for Coupled 3D Flow calculations.

    Resolution

    To resolve this issue you can do any of the following.

    • Re-run the analysis on a computer with more memory.
    • Re-run the analysis on a 64-bit computer.
    • Turn the AMG matrix solver for Coupled 3D Flow calculations Off.
    To turn the AMG matrix solver for Coupled 3D Flow calculations Off.
    1. Click Analysis File:Simulation_Moldflow/enu/2013/Help/Adviser/2076-Error_an2076/3160-Solver_m3160/ac.menuaro.gif Process Settings Wizard File:Simulation_Moldflow/enu/2013/Help/Adviser/2076-Error_an2076/3160-Solver_m3160/ac.menuaro.gif Advanced options. The Fill+Pack Analysis Advanced Options dialog appears.
    2. From the Solver Parameters section, click Edit. The Thermoplastics injection molding solver parameters (3D) dialog appears.
    3. From the Solver Setup section, click Solver parameters. The Solver Parameters dialog appears.
    4. Select Off from the AMG matrix solver selection drop-down list.