The Wire pairs within critical clearance result is generated by a 3D Microchip Encapsulation analysis when the selected analysis sequence includes Wire Sweep.
The plot shows the number and location of wire pairs for which predicted clearance between the wires is within the critical clearance.
NoteThe value is specified in the solver parameters. The default value is zero, indicating that the surfaces of adjacent wires can touch.
Using this result
Use this information to identify pairs of wires that are too close together after wire deformation occurs during cavity filling.
NoteIn order to calculate the
Wire pairs within critical clearance result, the wire sweep calculation must be performed in
Autodesk Simulation Moldflow Insight.
TipThis option is set on the
Microchip Options tab of the
Reactive Molding solver parameters (3D) dialog. Double-click

in the Study Tasks pane, or click

() to open the
Process Settings Wizard. Click to display the
Profile Settings page; click ; click in the
Solver parameters area; and click the
Microchip Options tab. Set the option to
Autodesk Simulation Moldflow Insight.